Sistemas de tratamiento de agua

Sistemas comerciales de tratamiento de agua RO para la producción de agua embotellada

Sistemas industriales de ósmosis inversa diseñados para plantas de bebidas y agua embotellada con capacidad de 0,5 a 50 T/H, membranas DOW USA FilmTec, desalinización de 99,6%. Adaptamos cada etapa de RO a la línea de llenado correspondiente para que sus especificaciones de calidad y rendimiento del agua lleguen a la botella, no solo al tanque de almacenamiento.

  • Capacidad 0,5-50 T/H (3.170-317.000 GPD)
  • Membrana RO DOW USA
  • SS304 / SS316 Construir
  • Garantía de 2 años
  • Respuesta del ingeniero las 24 horas
Commercial RO Water Treatment System
Industrial Reverse Osmosis Equipment
Bottled Water Production Plant
SS304/SS316
Sistema principal 304
torre ozono 316
RO
DOW USA FilmTec
Membrana RO salobre BW30
FDA
21 CFR 165.110
Referencia de la regla del agua embotellada
GMP
21 CFR Parte 129
Diseño GMP embotellador
CE
Marcado CE
Cumplimiento de las exportaciones de la UE
GRASA
Prueba de aceptación de fábrica
Validación previa al envío

Las plantas de bebidas y agua embotellada necesitan pureza de grado de membrana. Así es como lo ofrece nuestro sistema de RO

El desafío

Vulnerabilidades del agua cruda

Los embotelladores se devuelven para su auditoría, pierden lotes o se ven obligados a reelaborarlos cuando el agua de origen se entrega con exceso de sedimentos, cloro libre, dureza, hierro disuelto o carga microbiológica para la que nunca estuvieron destinados los filtros domésticos.

El carbón activado estándar elimina el cloro y el olor, pero no puede eliminar el total de sólidos disueltos; los filtros de sedimentos atrapan partículas de más de 5 micrones pero dan la bienvenida al paso de los minerales disueltos; El UV por sí solo acaba con los microorganismos pero deja inalterados los iones que afectan el sabor. El ciclo de la raíz es una sola etapa frente a un perfil de agua de alimentación multivariable.

“Especificamos DOW FilmTec BW30 porque podemos especificar un rechazo mínimo de NaCl de 99,5% en la hoja de datos del fabricante -ñona y esa cifra indica algo al equipo de control de calidad del comprador. Las membranas genéricas no llevan ese ancla”

Equipo de Ingeniería de Tecnología de Masas

Industrial Reverse Osmosis Water Treatment Plant with DOW FilmTec Membranes
La solución

Secuencia de pretratamiento e integración de DOW FilmTec

Nuestro sistema de tratamiento de agua elimina el ciclo con una secuencia constante de cuatro etapas de alimentación previa al tratamiento con membranas DOW FilmTec RO (la ósmosis inversa es un proceso de separación impulsado por pasos inversos que pasa una película semipermeable Porgef ordenando a una membrana que empuje agua purificada a través de ella y se sujete a los sólidos disueltos 'aceptado por la FDA 21 CFR 165.110 como técnica autorizada de purificación de agua embotellada).).

Cada programa tiene un tamaño en incrementos desde plantas de entrada de 0,5 T/H hasta embotellado regional de 50 T/H, con agua purificada saliendo del sistema con menos de 50 ppm de TDS incluso cuando el agua de alimentación alcanza las 800 ppm ñan confirmadas por ejecuciones industriales recientes.

Empleamos la misma placa de identificación de membrana y el mismo diseño utilizado por los principales embotelladores a nivel mundial, provistos de la transparencia de compras y la estructura de servicio posventa que exigen los compradores internacionales. Desde el ensamblaje deslizante hasta FAT (Pruebas de aceptación de fábrica), cada componente se selecciona para evitar cuellos de botella en la línea y extender la vida útil de la membrana.

Sistema de Tratamiento de Agua RO Industrial

Diseñado para una confiabilidad absoluta. Nuestras soluciones comerciales de ósmosis inversa están diseñadas para desalinización de alto rendimiento, brindando una pureza de agua sin concesiones para aplicaciones industriales y de embotellado exigentes.

Commercial RO Water Treatment System

Especificaciones técnicas

Rango de capacidad
0,5 T/H -contra 50 T/H
Tasa de desalinización
≥99.5%
Tasa de recuperación
50% --75%
Presión de funcionamiento
1,0 -1,5 MPa
Elemento RO
DOW FilmTec / Toray
Sistema de control
Siemens PLC + HMI

⚠¦ Información crítica sobre adquisiciones

Únicamente en términos de adquisiciones, el error más común que vemos es que los compradores dimensionan el sistema de ro comercial a partir de la tasa de embotellado nominal, sin tener en cuenta el tiempo de inactividad del CIP y la tasa de recuperación de la propia pila de RO. Una línea de llenado de 10.000 BPH, con 16 horas de funcionamiento, requerirá aproximadamente 8 m/h de agua purificada terminada.

Integración perfecta

Referencia cruzada: cada modelo Topilp NC en esta escalera se integra perfectamente con nuestra línea de producción de jugo de relleno caliente en el lado del almíbar-agua y con el etiquetado OPP termofusible para botellas de PET aguas abajo «lo que le permite tratar con un proveedor desde el agua. al palet.

Configuración comercial ligera

Para aplicaciones comerciales ligeras de ósmosis inversa (embotelladores boutique, estaciones de recarga de 5 galones, sistemas de agua para hotelería que rocían menos de 4000 BPH), el nivel MS-RO-500 del modelo ofrece agua purificada de alta calidad sin la carga de capital que asociamos con Sistemas industriales comerciales de agua de ósmosis inversa.

Configuración de plantas RO comerciales masivas

Nuestra línea comercial de sistemas de ósmosis inversa analiza seis niveles abstractos de capacidad, cada uno diseñado en torno a un objetivo definitivo de rendimiento de embotellado. Si bien la competencia revela solo dos o tres opciones de modelo, publicamos toda la escalera porque la capacidad RO ideal está dictada por sus botellas por hora de la línea de llenado, no por un contenedor vago “pequeño/medio/grande”. Los datos a continuación coinciden con cada sistema ro comercial con el rendimiento de la línea de llenado que admite de forma no intermitente, incluida una contingencia 20% para interrupciones de línea y ciclos CIP.

Modelo Capacidad de RO (T/H) Galones por día (GPD) Línea de llenado coincidente (BPH) Elementos RO (8«) Potencia de la bomba (kW) Rango TDS típico
MS-RO-500 0.5~3,170 2,000–4,000 Equivalente a 2× BW30-365 3.0 Hasta 1.500 ppm MS-RO-2000
MS-RO-2000 2~12,700 6,000–10,000 4× BW30-365 5.5 Hasta 2.000 ppm MS-RO-5000
MS-RO-5000 5~31,700 12,000–18,000 8× BW30-365 11 Hasta 2.500 ppm MS-RO-10000
MS-RO-10000 10~63,400 24,000–30,000 16× BW30-365 22 Hasta 3.000 ppm (BWRO) MS-RO-20000
MS-RO-20000 20~127,000 30,000–36,000+ 32× BW30-365 37 Salobre (configuración BWRO) MS-RO-50000
MS-RO-50000 50~317,000 Multilínea (personalizado) 80× BW30-365 90 Específico del proyecto --
Salida del frasco objetivo (500 ml) Modelo recomendado Bucle de pretratamiento Estándar de desinfección
Menos de 4000 BPH (boutique / 5 galones) MS-RO-500 Carbono + Suavizante + 5μm UV (XP-UVC-25W)
4.000-10.000 BPH (entrada comercial) MS-RO-2000 Arena + Carbono + Suavizante + 5μm UV + Ozono (MS-AF-3)
10.000-24.000 BPH (embotellador de nivel medio) MS-RO-5000 / 10000 4 etapas completas con redundancia UV + Ozono (MS-AF-5/7)
24.000-36.000+ BPH (regional) MS-RO-20000 / 50000 Copia de seguridad completa de 4 etapas + UF UV + Ozono (MS-AF-10)
Nota técnica: los caudales enumerados se calculan mediante recuperación de 15% con 2000 ppm de materia prima de NaCl a 225 psi y 25C ñona la condición de prueba ideal del productor para elementos DOW FilmTec BW30. Para materias primas superiores a 3000 ppm de TDS o agua salobre de acuífero, configuramos el mismo chasis con componentes de agua salobre RO (BWRO) que operan a mayor presión y rangos de recuperación más amplios. Cada modelo se envía preparado para fábrica, pretubo y probado.

Pila de pretratamiento de RO: del agua cruda al listo para la membrana

La purificación industrial del agua falla en la membrana porque la pila de pretratamiento delante del sistema de ósmosis inversa era demasiado corta o se producía de manera demasiado genérica para el agua de alimentación. Las plantas masivas emplean un tren de pretratamiento de cuatro etapas antes de cada RO principal, donde cada etapa crea una salida específica que esponja la membrana aguas abajo y extiende la vida útil del elemento de membrana. Los objetivos de eliminación a continuación se traducen de las líneas guía de calidad del agua de alimentación del manual técnico DOW FilmTec, que representan el límite superior de sobrecarga de TDS que la membrana RO puede soportar sin ensuciarse, extendiendo la eficiencia de recuperación y rechazo.

Etapa 01
Multi-Media Quartz Sand Filter Stage 1

Filtro de arena de cuarzo multimedia

Elimina Sólidos en suspensión, óxido, coloides, partículas >20 μm
Objetivo: Turbidez < 0,5 NTU; IDE <5
Etapa 02
Activated Carbon Filter Granular Stage 2

Filtro de Carbono Activado (granular)

Elimina Cloro libre, pesticidas, color, olor, materia orgánica
Objetivo: Cl2 libre < 0,1 mg/L; IDE <4
Etapa 03
Cation Resin Softener Na-form Stage 3

Suavizante de resina catiónica (forma Na)

Elimina Dureza del calcio y magnesio (iones Ca²+, Mg²+)
Objetivo: Dureza total < 1 ppm como CaCO3
Etapa 04
5-μm Cartridge Micron Filter Stage 4

Filtro de micras de cartucho de 5 µm

Elimina Finos residuales, arrastre de perlas de resina, partículas >5 μm
Objetivo: IDE < 3 (listo para RO)

La calidad de la pila de pretratamiento es el determinante más grande de cuánto tiempo puede durar una membrana RO.

Los datos de nuestra industria indican que el promedio regional vende membranas ro comerciales que sobreviven de tres a cinco años, versus de cinco a siete años para la membrana RO industrial -contra si y sólo si, el pretratamiento es efectivo y sostenible. No está en la membrana, sino en lo que llega a ella. El cloro libre por encima de 0,1 mg/L oxidará inmediatamente la capa de poliamida y provocará que un elemento BW30 falle en cinco o seis meses; la dureza superior a 1 ppm escala la superficie de la membrana y hace que requiera CIP prematuro. Ambos fallos apuntan hacia un sistema de pretratamiento demasiado simplificado.

En casos de agua de alimentación salobre o con alto contenido de TDS (regiones costeras, mezclas de reutilización, agua cruda de pozo), agregamos una quinta etapa de pretratamiento opcional: ultrafiltración (UF), utilizando membranas de PVDF de fibra hueca con un tamaño de poro de 0,01 «0,1 m. La UF puede eliminar seis registros de bacterias, más de cuatro registros de virus, y reducir la IDE por debajo de 3, lo que le da a la membrana un atributo de agua de alimentación ultralimpia, extendiendo la vida útil del elemento hacia el nivel superior. Podemos recomendar una ultrafiltración cuando su empresa clasifica el sistema de agua cruda con variabilidad persistente de turbidez, fluctuaciones orgánicas o cambios estacionales.

¿tiene un análisis de agua? Ingeniero de WhatsApp para una RFQ « envía el informe y especificaremos la pila de pretratamiento exacta dentro de un día hábil.

Obtenga una cotización instantánea

RO vs UF vs UV vs Ozono « La tecnología adecuada para el agua embotellada

Los embotelladores persisten en preguntar si una nueva tecnología puede hacer el trabajo de toda la pila del sistema de ósmosis inversa. La verdad honesta es que todas las soluciones vienen con compensaciones, y la tabla comparativa hace explícitas las compensaciones. Cada tecnología de la tabla elimina una clase diferente de contaminante, opera con un tamaño de poro diferente y consume un nivel diferente de energía. La ósmosis inversa comercial es el único paso en esta lista que disminuye significativamente el total de sólidos disueltos, razón por la cual FDA 21 CFR 165.110 aterriza en RO como límite de viaje en un Molwran determinado para producir agua embotellada. Desinfectar los rayos UV y el ozono; condición de carbono y suavizante; Pulidos UF; sólo desaliniza RO.

Tecnología Tamaño de poro / Mecanismo Lo que elimina Reducción de TDS SEC (kWh/m³) Mejor posición en pila
Ósmosis inversa (BW30) Membrana semipermeable de 0,0001 μm Sales disueltas, iones, metales pesados, bacterias, virus 97–99.6% 2.5-3.5 (sărțâit) Etapa principal de purificación
Ultrafiltración (UF) 0,01-0,1 μm de fibru hueca Sólidos en suspensión, bacterias, virus, coloides, macromoléculas No (no es un técnico de desalinización) 0.3–1.0 Pretratamiento RO o pulido independiente
Esterilizador UV UV-C de 254 nm, sin barrera física Bacterias, virus, protozoos (solo inactivación) No 0.02–0.08 Desinfección final antes del embotellado
Esterilizador de ozono O₃ injection, oxidation Microorganisms, taste, odor; provides residual No 0.08–0.15 Storage tank / pre-bottling residual
RO vs UF vs UV vs Ozone - Commercial Water Treatment Technology Comparison

System Architecture & Process Failures

Heedful of this, plant operators can compare the production specifications of commercial water filters and water Rumofags by single Specs (micron rating, flow), without realizing that a water Rumofags designed to generate sediment does not cover the same process space as a water Rumofags designed to generate pure water for bottled water. Each single technology described in the table above operates at a different point in the contaminant-class continuum, so that substituting one path without adjusting other components often trades an adequately known cost for an unknown failure mode.

The (practical) answer for a bottled water plant is a layered architecture: pretreatment reverse osmosis UV ozone, and if necessary UF, added when the feed profile indicates. Single-technology shortcuts (carbon-only Rumofags, UV-only “drinking water” units, or RO without disinfection) can save capital but end up failing downstream – either at the FDA chlorine residual ceiling, at the microbiological count test, or at the consumer taste test. We have traced each of these failure modes to retrofits where the original supplier specified one step too few to win a price comparison.

📊 Evaluating tech trade-offs?

Use our RO TCO Calculator — compares five-year energy and membrane replacement cost across configurations.

State-of-the-Art Water Treatment Manufacturing Facility

Precision Engineering & Strict Quality Control

Customer Outcome: From 800 ppm TDS Feedwater to Below 50 ppm Bottled Product

In a recent BoV water project, an MS-RO-5000 (5 T/H) was deployed onto a well water source that has 780-820 ppm TDS, hardness of about 280 ppm as CaCO, and free chlorine of about 0.4 mg/L, and suffered a downstream municipal blend before the four-stage pretreatment plus the DOW BW30 RO includes, the finished purified water had 38-46 ppm TDS, hardness < 1 ppm, free chlorine below detection, and it received final disinfection via the UVs and ozone stack.

In parallel with a 12,000 BPH filling line for 500 mL PET bottles, the RO was sized a tier up from nominal demand to accommodate CIP downtime and fit into puresitu production from the time it would take an equivalent sized commercial single-standby system to receive its first replacement.

TCO Optimization Snapshot — 5-Year Window

Energy is one of the two operating costs that primarily drive the bottled water plants’ operations economics is the cost of replacing the membrane membrane elements. With good pretreatment, industrial membranes tend to run five to seven years rather than the three-to-five-year usual commercial baseline – one replacement cycle that actually monetizes the use of a capital asset in the five-year national P.U.I. electricity cost environment.

Energy use for brackish RO falls into the industry benchmark range of 2.5 and 3.5 kWh per cubic metre fresh for industry standard benchmarking, with maintenance taking somewhere between 10 and 15% of total OPEX on water treatment systems. Industry-standard benchmarks for commercial water systems are above, but demands on the final TCO from a commercial reverse osmosis project are site per site and depend on feedwater profile, recovery speed, cost of energy in said site relative to global industry benchmarks. Commercial water treatment investments gain back within 5 years through high-quality purified water output and a less rework heavy bottling process, not necessarily by headlined price alone. Request your site-specific 5-year Cost Model.

Membrane Lifespan

5–7año
industrial w/ proper pretreatment

SEC Range

2.5–3.5kWh/m³
brackish RO baseline

Maintenance Share

10–15%
of total OPEX

CIP Cycle Interval

Quarterly
typical (water-quality dependent)

Extended Industrial Applications & Architecture

For bottled water product lines not in the mineral water or spring water class, the optional downstream remineralization stage of with a proprietary calcium, magnesium and bicarbonate profile can add the minerals onto the water in a dosage control skid – instead of relying on site water variability.

But this reverse osmosis system architecture can apply to many other waters forms, too – beverage formulation waters (juice, fruit tea, vegetable-protein beverage batch inputs), food processing industry-grade process water, pharmaceutical prepartion water to WHO and FDA standards, electronics-industry semiconductor fresh cleaning water, boiler feed water / cooling-tower makeup for power or process plant, seawater desalination through the BWRO chassis, and the the recycle side of industrial water treatment loops where wastewater polishes industrial waters prior to discharge or reuse. The application-specific variation is in pretreatment loop and disinfection residual, not in the main ro.

Certifications, Compliance and Materials

Global Regulatory Compliance Standards

Compliance anchor for any bottled water factory in international markets is the US FDA bottled water rule at 21 CFR 165.110, which establishes the allowable contaminant ceilings (including the 4.0 mg/L chlorine ceiling and the 0.7 mg/L fluoride ceiling when added). Our pretreatment series is sized to achieve finished-water levels comfortably below those ceilings: the activated carbon stage focuses on non-detectable free-chlorine while the RO main brings fluoride and the wider dissolved solid load down. Bottling process plant design complies with 21 CFR Part 129 (Processing and Bottling Good Manufacturing Practices), governing hygienic plant configuration, surface finish, and CIP capability.

Factory Acceptance Test (FAT) & Quality Documentation

All plants ship after a Factory Acceptance Test (FAT) at our Zhangjiagang facility, where we assemble your system and operate it on simulated feedwater consistent with your site analysis, while recording permeate quality across an eight hour cycle and preparing the results for your QA files before we ship it in the craters. We send you the FAT report before the container arrives on-site so that the set up it ready to go into production when it comes off the truck.

Procurement Guide: Pricing Factors, Lead Times, MOQ & After-Sales

International customers we work with most often have four questions about the water production set up: what influences system price, timing, minimum run length, and after-sales support. We provide transparent outlines on CAPEX, OPEX, lead-times, minimum order quantity, and the After-Sale scope. Buying transparency stands out as one of our strongest advantages in the industrial water treatment sector.

Lead Time & Warranty Specifications

Procurement Item Standard Offer Technical Notes
Lead Time (Standard) 30–45 days FOB Faster for MS-RO-500 / 2000 in stock configurations
Lead Time (Custom) 60–75 days FOB MS-RO-10000 and above; includes rigorous FAT cycle
Minimum Order (MOQ) 1 Set No minimum volume — single plant projects welcome
System Warranty 2 años Covers all machine parts. Excludes consumables (membranes, lamps, cartridges)
Respuesta del ingeniero Within 24 Hours Via Email, WhatsApp, and scheduled technical calls
Parts Dispatch 5 días laborables International courier dispatch direct from Zhangjiagang stock
FAT (Factory Acceptance Test) Incluido Full performance validation completed prior to shipping
BOQ / RFP Support Available Engineering team drafts BOQ entries matched to your specific tender format

Tender & RFP Preparation Support

One source of operational frustration in regulated markets is the sheer size of tender packs—often exceeding 100 pages. We include dedicated writing personnel on our quote team to produce technical inserts based on your unique water analysis, flow rate requirements, and application preferences, ensuring your tender document arrives ready to submit.

Obtener cotización de planta

Commercial RO System Engineering Tools

Selector de capacidad RO

Tell us your bottling target and feedwater profile — we recommend the right Mass commercial RO system and matched filling line.

Launch Selector

Calculadora RO TCO « Ventana de 5 años

Estime el costo total de propiedad a 5 años para su sistema de RO comercial. Compara el impacto de la calidad del pretratamiento en la vida útil de la membrana y la economía energética.

Calculate TCO

Comprobador RO-Fit de agua de alimentación

Enter your raw water analysis. We benchmark against DOW FilmTec BW30 feedwater limits and recommend the pretreatment stack your RO needs.

Check Compatibility

FAQ — From RFQ to Operations

Para una línea de PET de 500 ml que funciona con 10.000 botellas por hora en un sistema de ósmosis inversa continua alimentada en turnos de 16 horas, está produciendo aproximadamente 80 m³ de agua purificada terminada por día una vez que tiene en cuenta el enjuague, los ciclos CIP y el volumen de rechazo de calidad. Eso coloca el sistema en el nivel MS-RO-5000 (5 T/H, ~120 m³/día) con un espacio libre cómodo «recomendamos dimensionar un nivel por encima de su clasificación de embotellado para que el RO no se convierta en el cuello de botella de la línea durante los turnos pico. El nivel MS-RO-10000 se vuelve apropiado una vez que escala a 18 000-24 000 BPH o ejecuta operaciones continuas de tres turnos.
Una configuración de solo carbono elimina el cloro libre y mejora el sabor, pero no hace nada con respecto a sedimentos por encima de 5 micrones, dureza de calcio y magnesio o sólidos disueltos en general. Hacer funcionar una membrana RO aguas abajo del pretratamiento solo con carbono es la causa más común de falla prematura de la membrana en sistemas comerciales de bajo costo. La dureza escala la membrana y fuerza los ciclos CIP en meses en lugar de años. Nuestra pila de cuatro etapas (arena → carbono → ablandador → filtro de micras) lleva la IDE por debajo de 3 y el cloro libre a no detectable antes de que el agua de alimentación llegue a la RO principal, que es lo que permite que la membrana corra hacia el extremo superior de su vida útil industrial. rango de cinco a siete años.
Ambos. Nuestro sistema comercial de tratamiento de agua RO en esta página cubre el camino del lado del agua desde la entrada de agua cruda hasta el tanque de almacenamiento: pretratamiento, RO principal, UV, ozono y tanque de agua terminada. Para una planta embotelladora llave en mano ampliamos el paquete aguas abajo con líneas de llenado (2000-36000 BPH para agua, 50-2000 BPH para barriles de 5 galones), etiquetado termorretráctil, etiquetado por fusión en caliente OPP, moldeo por soplado de botellas y producción de preforma de PET. Una ventaja de integración es un proveedor para la ruta completa de agua a paleta, lo que elimina el problema de coordinación de la interfaz que vemos cuando los compradores compran líneas de tratamiento y llenado de agua de proveedores separados.
DOW FilmTec BW30 elements are rated at 99.5% NaCl rejection minimum under the manufacturer’s standard test condition (2,000 ppm NaCl at 225 psi, 25°C, pH 8, 15% recovery). In real plant operation, system-level desalination lands in the 97–99.6% range depending on feedwater composition, recovery rate, and how long the membrane has been in service. Our engineers commission every plant against your specific feedwater profile during the FAT cycle, so the desalination rate you see in operation is documented before the system leaves our facility.
Los datos de la industria muestran que las membranas RO comerciales duran de tres a cinco años en promedio, mientras que las membranas RO industriales alcanzan de cinco a siete años cuando el pretratamiento se dimensiona y mantiene adecuadamente. La frecuencia de reemplazo depende casi por completo de lo que llega a la membrana: la calidad del agua de alimentación, la integridad de la eliminación de cloro en etapa de carbono, el ciclo de regeneración del suavizante y la disciplina trimestral CIP. En una ventana operativa de cinco años, una planta bien administrada según nuestras especificaciones normalmente ve un ciclo completo de reemplazo de membrana; las plantas con tratamiento insuficiente ven dos o más. El elemento de la línea de membrana es uno de los componentes OPEX más grandes a cinco años y el más fácil de extender mediante inversiones previas al tratamiento.
Sí. La escalera anterior enumera los puntos estándar del modelo MS-RO, pero el chasis subyacente es modular: recuento de elementos, tamaño de la bomba y configuración del volumen del tanque de almacenamiento entre niveles. Un chasis modular nos permite construir plantas de 1,5, 3, 7, 15, 25 y 30 T/H cuando su índice de embotellado se encuentra entre peldaños estándar, con un plazo de entrega de 30 a 45 días por debajo de MS-RO-10000.
La garantía de dos años cubre todas las piezas de la máquina en el sistema comercial de tratamiento de agua RO «bombas, válvulas, paneles de control, instrumentación, marcos, tuberías y soldaduras de tanques « durante los 24 meses completos desde la entrega FOB. Los consumibles (membranas RO, lámparas UV, cartuchos, resina, medios de intercambio iónico) están excluidos porque su vida útil depende de sus condiciones operativas más que de la calidad de construcción. Una respuesta de ingeniero las 24 horas significa que un ingeniero de aplicaciones de nuestro equipo de Zhangjiagang responde a su consulta técnica dentro de un día hábil a través de correo electrónico, WhatsApp y videollamadas programadas; para fallas cubiertas por garantía, envío de piezas de repuesto a través de mensajería internacional dentro de los cinco días hábiles.
Cada planta con capacidad MS-RO-2000 y superiores se envía con instalación en el sitio y capacitación del operador como parte del alcance estándar, programado conjuntamente con el cronograma de su proyecto. El trabajo del sitio cubre el posicionamiento del sistema, la interconexión de tuberías con su fuente de agua y línea de embotellado existentes, la puesta en servicio eléctrica y de instrumentación, y un programa de capacitación del operador de varios días que cubre la operación de rutina, la disciplina CIP y el programa de mantenimiento que mantiene la membrana en el extremo más largo del rango de vida industrial. Cada prueba de aceptación de fábrica se ejecuta en nuestras instalaciones contra agua de alimentación simulada que coincide con el análisis de su sitio, y el informe FAT «, que incluye registros de calidad del agua permeada a lo largo del ciclo de prueba, lecturas gratuitas de cloro y SDI en cada etapa de pretratamiento y la tasa de recuperación contra su TDS especificado « se envía con los registros del sistema para su archivo de control de calidad. Cuando las regulaciones locales requieren una prueba de aceptación del sitio, nuestros ingenieros la ejecutan en su piso una vez completada la puesta en servicio, con documentación de aprobación preparada en el formato que su organismo regulador o marco QMS requiere. Para las plantas que exportan a los Estados Unidos, la Unión Europea o la región del CCG, coordinamos los paquetes de documentación adicionales que las autoridades aduaneras y de seguridad alimentaria normalmente solicitan durante el ciclo de importación o registro, para que su planta de agua embotellada pueda comenzar la operación comercial a tiempo en lugar de esperar la documentación en tránsito.

Ready to Spec Your Commercial RO Water Treatment System?

Tell us your bottling throughput target and include a recent water analysis from your site. We will respond with a footprint recommendation, pretreatment scope outline, and a preliminary budget within 48 hours for your review – including warranty and after-sale framework details as international buyers expect.
Obtener cotización de planta

Why We Build This RO System

Mass Technology has been manufacturing complete water treatment and bottling lines from Zhangjiagang since the company’s founding, with the 0.5 to 50 T/H ladder built around the bottling capacities (2,000 to 36,000 BPH) we ship in matched plant projects. Specifications on this page come from our engineering files and the DOW FilmTec public datasheets we anchor every commercial RO bid against — published here in full because international buyers should not have to ask twice for the numbers a serious supplier already knows.